Tulip Combi
TULIP COMBI – TUMESCENT LIPOSUCTION SYSTEM
Tulip Combi is a combination surgical pump system used in tumescent liposuction procedures for fast
removal of body fat from subcutaneous layers. The infiltration pump is provided with a flow rate
(30-300 ml/min) control through a footswitch for precise infusion of tumescent fluid. The infused volume
per fat pocket/body limb as well as cumulative infused volume can be digitally monitored.
The oil less piston vacuum pump produces a high vacuum (-700mm Hg) at a high evacuation rate
(90 litres/min) capable of sucking out even the stickiest fat mass. The whole equipment operates at a
very low noise level (56 db) and is wheel mounted for easy mobility
SALIENT FEATURES
> Imported 90 Liters/min high power oil – free piston vacuum pump
> Digital footswitch controlled variable infiltration (30-300 ml/min)
> Imported roller pump for infiltration and piston pump for suction
> Imported Anti-bacterial filter provided in suction line eliminates air borne contamination
> Efficient overflow/backflow protection float assembly provided for suction jars.
> Transparent high quality polycarbonate jars with graduation marks.
> Changeover valve provided for selection of suction jars of different capacities.
> Variable Max. vacuum.
> Suction unit can also be used for laparoscopic surgeries as well as open procedures.
> Compact, relatively silent operation (< 56 db) with mobility is an added advantage.
> 0.3 HP Motor – low power consumption.
> Rated for 8-hour continuous duty.
> Rust free , long life powder Coated Aluminum body.
STANDARD ACCESSORIES
Suction jar (Polycarbonate) 4 litres capacity: 1 No.
Suction jar (Polycarbonate) 2 litres capacity: 1 No.
Single pedal footswitch: 1 No.
Infiltration tubing (silicone rubber tube): 1 Set
Liposuction tubing (silicone rubber tube): 2 Sets
Hydrophobic filters: 2 Nos
APPLICATIONS
> Liposuction – Cosmetic Surgery
TECHNICAL SPECIFICTION
Infiltration Pump
Infusion rate: 30-300ml/min (Upgradable to 600ml/min)
Infused volume: 0 – 9.99 litres
Cumulative volume: 0 – 99.9 litres
Memory for infusion: Digital display provided
Infusion control: Through single pedal footswitch
Power consumption: 50 watts
Suction Pump
Max. Vacuum: (-) 700mm Hg (Variable)
Free flow rate: 90 litres/min
Suction jars (polycarbonate): 4 litres + 2 litres
Noise level: <56 db
Tubing: Autoclavable
Power consumption: 180 watts (0.3 HP)
Physical dimension: 360 x 385 x 740mm
Total power consumption: 230 watts (230 V, 50 Hz.)
Mounting: Trolley mounted
Gross weight: 30 Kg
*Due to continuous improvement in design for compliance with international standards, the technical specifications & physical appearance is subject to alterations without notice.