RF Arc

RF Arc

Why4 MHz?

Higher the operating frequency, lesser the lateral spread and lesser rise in temperature at surgical site. This is exactly what happens with the 4 MHz produced by the RF ARC in both bipolar and monopolar modes.

 

The major advantages of 4 MHz RF ARC are

> Energy is administered gently and in a highly focused fashion.

> Pressure-less incision

> Preservation of tissue tautness

> Minimal necrosis compared to conventional units

> No carbonistaion / charring

> Quicker wound healing due to lower temperature and lower necrosis

> No recurrent bleeding

> Excisions taken can be examined histo-pathologically

 

SALIENT FEATURES

> Full 4 MHz Output for Monopolar and Bipolar

> Two types of monopolar cut – Fine Cut and Heavy Cut

> Two types of monopolar coag – Forced Coag and Soft Coag

> Two types of bipolar coag – Macro Coag and Micro Coag

> Monopolar Outputs via handswitch Pencil / Double pedal Footswitch

> HF output power can be set digitally in small increments

> Steady HF output at set value even under line voltage fluctuating conditions

> Audio & visual monitoring of patient plate circuit

> Combined or independent use of mono & bipolar functions enabled

> Separate generators for monopolar and bipolar functions

> Autoclavable accessories

STANDARD ACCESSORIES

> Colour coded two pedal footswitch with cable and connector.

> Silicone Rubber patient plate with detachable connection cable.

> Reusable Active electrode handle with set of 4 electrodes & silicone rubber insulated cable

> Reusable Insulated bipolar forceps with silicone rubber insulated cable.

> Handswitch surgical pencil with cable

APPLICATIONS

> General / Open Surgery

> Neuro Surgery

> ENT Surgery

> Cosmetic Surgery

> Conization

> Discoplasty

> Tonsillectomy

> Hemorrhoids

> Wart and corn removal

TECHNICAL SPECIFICTION

TECHNICAL SPECIFICATIONS

HF Power Display: 3-digit LED display

HF Power control: Digital control in small increments Rated frequency: 4 MHZ

Design: Voltage Independent Performance

Monopolar Fine Cut: 150 watts (variable) Monopolar Heavy Cut: 150 watts (variable)

Monopolar Forced Coag: 100 watts (variable) Monopolar Soft Coag: 120 watts (variable)

Bipolar Macro Coag: 120 watts (variable)

Bipolar Micro Coag: 60 watts (variable)

Size: 350mm x 325mm x 135 mm

Weight: 5 Kgs

Power consumption: 350 Watts (230V, 50Hz)

 

*Due to continuous improvement in design for compliance with international standards, the technical specifications & physical appearance is subject to alterations without notice.

 

Scroll to Top