RF Arc
RF Arc
Why4 MHz?
Higher the operating frequency, lesser the lateral spread and lesser rise in temperature at surgical site. This is exactly what happens with the 4 MHz produced by the RF ARC in both bipolar and monopolar modes.
The major advantages of 4 MHz RF ARC are
> Energy is administered gently and in a highly focused fashion.
> Pressure-less incision
> Preservation of tissue tautness
> Minimal necrosis compared to conventional units
> No carbonistaion / charring
> Quicker wound healing due to lower temperature and lower necrosis
> No recurrent bleeding
> Excisions taken can be examined histo-pathologically
SALIENT FEATURES
> Full 4 MHz Output for Monopolar and Bipolar
> Two types of monopolar cut – Fine Cut and Heavy Cut
> Two types of monopolar coag – Forced Coag and Soft Coag
> Two types of bipolar coag – Macro Coag and Micro Coag
> Monopolar Outputs via handswitch Pencil / Double pedal Footswitch
> HF output power can be set digitally in small increments
> Steady HF output at set value even under line voltage fluctuating conditions
> Audio & visual monitoring of patient plate circuit
> Combined or independent use of mono & bipolar functions enabled
> Separate generators for monopolar and bipolar functions
> Autoclavable accessories
STANDARD ACCESSORIES
> Colour coded two pedal footswitch with cable and connector.
> Silicone Rubber patient plate with detachable connection cable.
> Reusable Active electrode handle with set of 4 electrodes & silicone rubber insulated cable
> Reusable Insulated bipolar forceps with silicone rubber insulated cable.
> Handswitch surgical pencil with cable
APPLICATIONS
> General / Open Surgery
> Neuro Surgery
> ENT Surgery
> Cosmetic Surgery
> Conization
> Discoplasty
> Tonsillectomy
> Hemorrhoids
> Wart and corn removal
TECHNICAL SPECIFICTION
TECHNICAL SPECIFICATIONS
HF Power Display: 3-digit LED display
HF Power control: Digital control in small increments Rated frequency: 4 MHZ
Design: Voltage Independent Performance
Monopolar Fine Cut: 150 watts (variable) Monopolar Heavy Cut: 150 watts (variable)
Monopolar Forced Coag: 100 watts (variable) Monopolar Soft Coag: 120 watts (variable)
Bipolar Macro Coag: 120 watts (variable)
Bipolar Micro Coag: 60 watts (variable)
Size: 350mm x 325mm x 135 mm
Weight: 5 Kgs
Power consumption: 350 Watts (230V, 50Hz)
*Due to continuous improvement in design for compliance with international standards, the technical specifications & physical appearance is subject to alterations without notice.